Panels ālining upā ā also a symptom of modern metal roofing. Since they are not intersecting pans and interrupt them for z bar and cap, itās customary and considered workmanlike to align the pan seams on either side of a hip, or ridge. In seamed work, this is the opposite because folding two intersecting seams into a double lock is very difficult and provides no added value. It is sometimes done by very good folders to āshow offā essential how perfect their notching is, but generally itās frowned upon because again it adds risk, (of folds not completing well) with no added value other than aesthetics. ā Kurtis Hord
https://www.stortz.com/ridge-detail-answering-youtube-comments/